Search: Advanced search
Select language:
Printable version 
Categories Categories
Honeywell Recorders
Honeywell Controllers
Honeywell Burner Controls
Honeywell Modutrol Motors
Honeywell pH, ORP, Conductivity
Chessell Recorders
Eurotherm Controllers
Calibration Equipment
Dry Block Calibrators & Baths
Fluke Instruments
Flow & Level
Magmeters
Pressure Calibrators
Pressure Transmitters
Temperature
UV-VIS Spectrophotometers
Thermal Imagers
Humidity
IR Thermometers
Oxygen Analyzers
Refractometers
Electrical Test
Combustion Analyzers
Digital Displays & Panel Meters
Analytical Balances
Gas Monitors


Bestsellers Bestsellers
1. Altek Model 830
2. Transcat MF880 Multifunction Calibrator
3. Condec Pressure Calibrator
4. Altek Model 934
5. Transmation 1045-02 Dc Process Signal Calibrator 220 Volt


Special Special
Gift certificates


Help Help
Contact us
Privacy statement
Terms & Conditions

Moyer Instruments, Inc. :: Calibration Equipment :: Transcat MF880 Multifunction Calibrator

Transcat MF880 Multifunction Calibrator

Transcat MF880 Multifunction Calibrator 
Transcat MF880 Multifunction Calibrator.

Transcat Model # MF880
High Accuracy to ±0.015% of reading
Measure and Source: Thermocouples (13 types), RTDs (13 types), Current, Voltage, Frequency, and Pulse
Isolated mA/V Circuit for Complete Transmitter Calibration
Pressure Module Input for Transcat Modules
Menu-Driven Functions
Direct Numeric Keypad for Quick Set-up
Programmable Setpoints Speed Calibrations
Built-on 250W Resistor for HART™ Compatibility with Smart Transmitters
Meets CE Requirements
Desinged to IEC 1010 Safety Standards
Voltage: Source 0.000 to 20.000 VDC / Read Isolated 0.000 to 30.000 VDC
Current (mA): Source 0.000 to 52.000 mA / Read Isolated 0.000 to 24.000 mA, Non Isolated 0.000 to 52.000 mA
Thermocouple/mV: -10.000 to +75.000 mV
CPM/Hz/kHz Frequency: 2.0 to 600.0 CPM / 1.0 to 1000.0 Hz / 1.0 to 10.00 Hz
Pulse Frequency (Source only): 1 to 30000.0 pulses; 2 CPM to 10kHz, selectable amplitude
Ohms: Source 5.0 to 4000W / Read 0.00 to 4000.0W
Current mA Accuracy: ±0.015% of reading ±2µA
Voltage Accuracy: ±0.015% of reading ±2 mV
Thermocouple/mV Accuracy: ±0.02% of reading ±10µV
Typical Accuracy: J ±0.2 °C and K ±0.3° C
RTD (Pt100 385) Accuracy: ±0.2 °C
Ohms Accuracy: ±0.025% of reading ±0.05; maximum Works with all pulsed transmitters down to 5ms
Frequency Accuracy: ±0.05% of reading maximum
Pressure Module Accuracy: ±(0.025% of reading ±0.025% FS)
Size/Weight: 7.5"H x 4.0"W x 1.5"D/20 ounces

Details
 
SKU SKU_24
Weight 2.00 lbs
Price: $1692.00

Options
 
Option
Quantity

Add to cart
        
Add to wish list


 

Send to friend

Your name: *
Your e-mail: *
Recipient email: *

Send to friend
 

Recommends list

Customers who bought this product also bought the following products:  

 

Your cart Your cart
Cart is empty
 

View cart
Checkout
Wish list
Orders history


Authentication Authentication
Username

Password

Log in 
Register 
Recover password

If you have disabled Javascript in your browser click here


News News
No news available at the moment

Your email:
Subscribe 





Copyright © 1981-2008 Moyer Instruments, Inc.
Website Design by The PSI Website Development Company